FARWEST PAINT MFG CO -- 1071, YELLOW TRAFFIC LINE PAINT -- 8010-00N032928
=====================  Product Identification  =====================

Product ID:1071, YELLOW TRAFFIC LINE PAINT
MSDS Date:01/01/1992
FSC:8010
NIIN:00N032928
=== Responsible Party ===
Company Name:FARWEST PAINT MFG CO
Address:4522 S 133 ST
Box:68726
City:TUKWILA
State:WA
ZIP:98168
Country:US
Info Phone Num:206-244-8844
Emergency Phone Num:206-941-1619
CAGE:6F266
=== Contractor Identification ===
Company Name:FARWEST PAINT MANUFACTURING CO
Address:4522 SOUTH 133RD ST
Box:City:TUKWILA
State:WA
ZIP:98168
Country:US
Phone:206-244-8844
CAGE:6F266

=============  Composition/Information on Ingredients  =============

Ingred Name:TOLUENE  (SARA III)
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: 3.5%
OSHA PEL:200 PPM/150 STEL
ACGIH TLV:50 PPM; 9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:LIGROINE; (MINERAL SPIRITS 350)
CAS:8032-32-4
RTECS #:OI6180000
Fraction by Wt: 1.9%
OSHA PEL:100 PPM (MFR)
ACGIH TLV:100 PPM (MFR)

Ingred Name:VM & P NAPHTHA; (MINERAL SPIRITS 250)
CAS:64742-89-8
Fraction by Wt: 21.5%
Other REC Limits:PEL/TLV:250 PPM(MFR)
OSHA PEL:300 PPM, 400 STEL
ACGIH TLV:300 PPM

Ingred Name:LEAD SULFOCHROME;(CHROME YELLOW PIGMENT) CONTAINING
    INGREDIENTS 5-6.
CAS:1344-37-2
Fraction by Wt: 9.5%

Ingred Name:LEAD  (SARA III)
CAS:7439-92-1
RTECS #:OF7525000
Fraction by Wt: 58%
OSHA PEL:0.05 MG/M3
ACGIH TLV:0.15 MG/M3 DUST
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:CHROMIUM (VI) OXIDE(1:3);(CHROMATE)
CAS:1333-82-0
RTECS #:GB6650000
Fraction by Wt: 25.5%
Other REC Limits:PEL:0.1 MG/M3 (MFR)
OSHA PEL:0.1 PPM,C
ACGIH TLV:0.05 MG/M3

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:NO
Health Hazards Acute and Chronic:SKIN:MAY CAUSE IRRITATION,
    SENSITIZATION, OR DEFATTING OF SKIN UPON PROLONGED OR REPEATED
    CONTACT. INHAL:EXCESSIVE EXPOSURE TO VAPORS OR SPRAY MIST CAN
    RESULT IN HEADACHE, DIZZINESS, NAUSEA & LOSS OF  CONSCIOUSNESS.
    SOME REPORTS HAVE ASSOCIATED REPEATED & PROLONGED OCCUPATIONAL
    OVEREXPOUSRE TO SOLVENTS (EFTS OF OVEREXP)
Explanation of Carcinogenicity:CHROMIUM COMPOUNDS:KNOWN CARCINOGEN
    (NTP), GROUP 1 (IARC). LEAD:GROUP 2B (IARC).
Effects of Overexposure:HLTH HAZ:W/PERM BRAIN & NERV SYS DMG. EYE: MAY
    BE AN IRRITANT. NOTE:(TOLUENE CAS# 108-88-3, LEAD CAS# 7439-92-1)
    APPEAR ON NAVY LISTING OF OCCUPATIONAL REPRODUCTIVE HAZARDS.SEEK
    CONSULTATION FROM APPR OPRIATE HEALTH PROFESSIONALS
    CONCERNINGLATEST HAZARD LIST INFORMATION & SAFE HANDLING & EXPOSURE
    RECOMMENDATIONS.
Medical Cond Aggravated by Exposure:NONE WHEN USED IN ACCORDANCE WITH
    SAFE HANDLING PRECUATIONS.

=======================  First Aid Measures  =======================

First Aid:SKIN:PROMPTLY WASH W/SOAP & WATER. REMOVE & WASH ANY
    CONTAMINATED CLOTHING BEFORE REUSE. EYE:FLUSH WITH LARGE QTYS OF
    WATER FOR AT LEAST 15 MINUTES AND GET MD. INGEST:DO NOT INDUCE
    VOMITING, KEEP PERS ON WARM, QUIET & GET MD. ASPIRATION OF MATERIAL
    INTO LUNGS CAN CAUSE CHEMICAL PNEUMONITIS WHICH CAN BE FATAL.
    INHAL:MOVE TO FRESH AIR IMMED. IF RESPIRATORY SYMPTOMS DEVELOP, GET
    MD IMMEDIATELY.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:26F,-3.3C
Lower Limits:0.7%
Extinguishing Media:FOAM, CO2, DRY CHEMICAL, WATER FOG/USE ANY CLASS B
    EXTINGUISHING AGENT. WATER MAY BE UNSUITABLE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
    PROTECTIVE EQUIPMENT. EVACUATE AREA OF UNPROTECTED PERSONNEL. WATER
    SPRAY MAY BE USED TO KEEP CONTAINERS COOL.
Unusual Fire/Explosion Hazard:VAPORS MAY FORM AN EXPLOSIVE MIXTURE IN
    AIR & MAY BE IGNITED BY SPARKS, PILOT LIGHTS, ETC. CLOSED
    CONTAINERS MAY RUPTURE WHEN EXPOSED TO EXTREME HEAT.

==================  Accidental Release Measures  ==================

Spill Release Procedures:REMOVE ALL IGNIT SOURCES. VENT AREA. ABSORB
    SPILL WITH AN ABSORBENT MATERIAL SUCH AS SAWDUST, VERMICULITE OR
    SAND & PLACE MATL INTO CLSD CNTNR. IF LARGE SPILL, DIKE AREA TO
    PVNT MATL FROM ENTERING WAT ER SYS/SEWERS. WEAR PROT EQUIP DURING
    CLEANUP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID PROLONGED OR REPEATED INHALATION
    OF HEATED VAPORS OR SPRAY MISTS. KEEP AWAY FROM HEAT OR OPEN FLAME.
    MATERIAL MAY CAUSE SENSITIZATION.
Other Precautions:DO NOT GET IN EYES, ON SKIN OR CLOTHING. DO NOT ALLOW
    CONTAMINATED CLOTHING TO CONTACT SKIN. DO NOT WELD ON FULL OR EMPTY
    CONTAINERS. KEEP CONTAINERS CLOSED, WHEN NOT IN USE, & PROPERLY
    LABELED.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED CANISTER TYPE RESPIRATOR
    MUST BE WORN TO PREVENT INHALATION OF VAPORS OR SPRAY MIST WHEN TLV
    OR PEL EXCEEDED.
Ventilation:GEN VENT REQ DURING NORMAL USE. LOC VENT MAY BE REQ UNDER
    CERTAIN OPERS TO KEEP EXPOS LEVEL BELOW APPLIC INGRED LIMITS.
Protective Gloves:NITRILE, NEOPRENE OR RUBBER GLOVES.
Eye Protection:CHEM WORK GOGG/FULL LENGTH FSHLD .
Other Protective Equipment:PROTECTIVE CLOTHING TO PREVENT SKIN CONTACT.
    EYE WASH STATION & SAFETY SHOWER.
Work Hygienic Practices:WASH HANDS BEFORE EATING OR SMOKING.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

==================  Physical/Chemical Properties  ==================

HCC:F3
Boiling Pt:B.P. Text:>205F,>96C
Vapor Pres:53 @ 20C
Vapor Density:HVR/AIR
Spec Gravity:1.44 
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:NIL
Appearance and Odor:YELLOW LIQUID
Percent Volatiles by Volume:50

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDANTS, ACIDS, BASES AND EPOXY HARDENERS
    UNDER UNCONTROLLED CONDITIONS.
Stability Condition to Avoid:HEAT, SPARKS & OPEN FLAMES. IF PRODUCT
    CONTAINS ALUMINUM, MOISTURE IN CLOSED CONTAINERS WILL GENERATE
    HYDROGEN GAS.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION CAN YIELD CARBON
    MONOXIDE & TOXIC VAPORS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:CNTNRS SHOULD BE TREATED AS HAZ WASTE BASED ON
    CHARACTERISTIC OF IGNIT AS DEFINED UNDER RCRA REGS (40CFR261). DISP
    OF MATL/ITS CNTNR REQS COMPLIANCE W/APPLIC LABELING, PACKAGING, &
    RECORDKEEPING STAND ARDS. DISP MUST BE I/A/W LOC/STATE/FED REGS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.