SPRAYON PRODUCTS -- 00103 RUST BREAKER, LUBRICANTS, RUST (SUP DAT) -- 9150-00N078235
===================== Product Identification ===================== Product ID:00103 RUST BREAKER, LUBRICANTS, RUST (SUP DAT) MSDS Date:05/17/1993 FSC:9150 NIIN:00N078235 === Responsible Party === Company Name:SPRAYON PRODUCTS Address:6830 COCHRAN RD City:SOLON State:OH ZIP:44139 Country:US Info Phone Num:800-777-2966 Emergency Phone Num:216-292-7400 CAGE:09800 === Contractor Identification === Company Name:SHERWIN-WILLIAMS DIVERSIFIED BRANDS, INC. Address:26300 FARGO AVENUE Box:City:BEDFORD HEIGHTS State:OH ZIP:44146 Country:US Phone:216-292-7400 OR 216-595-8634 CAGE:09800 ============= Composition/Information on Ingredients ============= Ingred Name:ALKYLATE PETROLEUM DISTILLATES; (ALIPHATIC HC DISTILLATE) VP: 2.0 CAS:64741-73-7 Fraction by Wt: 82% OSHA PEL:100 PPM (MFR) ACGIH TLV:100 PPM (MFR) Ingred Name:ETHANOL, 2-BUTOXY-; (2-BUTOXYETHANOL) VP: 0.6 CAS:111-76-2 RTECS #:KJ8575000 Fraction by Wt: 2% OSHA PEL:50 PPM, S ACGIH TLV:25 PPM, S Ingred Name:MINERAL OIL, PETROLEUM DISTILLATE, SOLVENT DEWAXED (MILD), HEAVY PARAFFINIC; (HEAVY PARAFFINIC OIL) CAS:64742-65-0 RTECS #:PY8038500 Fraction by Wt: 13% OSHA PEL:N/K ACGIH TLV:N/K Ingred Name:CARBON DIOXIDE. VP: 760.0 CAS:124-38-9 RTECS #:FF6400000 Fraction by Wt: 2% OSHA PEL:5000 PPM ACGIH TLV:5000PPM/30000STEL Ingred Name:VOC AS PERCENT BY WEIGHT EXCLUDING FEDERALLY EXEMPT SOLVENTS: 84 RTECS #:9999999VO OSHA PEL:N/K ACGIH TLV:N/K ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO Health Hazards Acute and Chronic:ACUTE: IRRIT OF EYES, SKIN & RESP SYS. MAY CAUSE NERV SYS DEPRESS. EXTREME OVEREXP MAY RSLT IN UNCON & POSS DEATH. SIGNS & SYMPS OF OVEREXP: EXCESS EXPOS TO VAPS/SPRAY MISTS MAY CAUSE HDCH, DIZZ, NAUS & LOSS OF COORD. EXCESS SKIN & EYE EXPOS MAY CAUSE REDNESS & ITCH/BURNING SENSATION. CHRONIC: PRLNG (EFTS OF OVEREXP) Explanation of Carcinogenicity:MILDLY REFINED MINERAL OIL (CAS # 64742-65-0): IARC MONOGRAPHS, SUPPLEMENT, VOLUME 7, PAGE 252, 1987: GROUP 1. Effects of Overexposure:HLTH HAZ: OVEREXP TO SOLV INGS MAY CAUSE ADVERSE EFTS TO LIVER, URINARY, BLOOD-FORMING, CARDIOVASCULAR & REPRO SYS. RPTS HAVE ASSOC RPTD & PRLNG OVEREXP TO SOLVS W/PERM BRAIN & NERV SYS DMG. ANIMAL ST UDIES CLEARLY DEMONSTRATED DOSE-RELAREDADVERSE EFTS ON CNS, HEMATOPOIETIC TISS, BLOOD, KIDNEYS & LIVER, ASSOC (SUP DAT) Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED. ======================= First Aid Measures ======================= First Aid:INHAL: REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP WARM & QUIET. SKIN: WASH AFFECTED AREA THOROUGHLY W/SOAP & WATER. REMOVE CONTAMINATED CLOTHING & LAUNDER BEFORE REUSE. EYES: FLUSH W/LARGE AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION. INGEST: NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. DO NOT INDUCE VOMITING. GIVE SEVERAL GLASSES OF WATER. SEEK MEDICAL ATTENTION. ===================== Fire Fighting Measures ===================== Flash Point Method:PMCC Flash Point:>200F,>93C Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM. Fire Fighting Procedures:WEAR NIOSH APPRVD SCBA & FULL PROT EQUIP . WATER SPRAY MAY BE INEFFECTIVE. IF WATER IS USED, FOG NOZ ARE PREF. WATER MAY BE USED TO COOL CLSD (SUP DAT) Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE DUE TO THE BUILD-UP OF PRESSURE WHEN EXPOSED TO EXTREME HEAT. ================== Accidental Release Measures ================== Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND REMOVE WITH INERT ABSORBENT. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:CONTENTS UNDER PRESSURE. DO NOT PUNCTURE, INCINERATE OR EXPOSURE TO TEMPERATURE ABOVE 120F. DO NOT TAKE INTERNALLY. KEEP OUT OF REACH OF CHILDREN. Other Precautions:HEAT FROM SUNLIGHT, RADIATORS, STOVES, HOT WATER, & OTHER HEAT SOURCES COULD CAUSE CONTR TO BURST. INTENTIONAL MISUSE BY DELIBERATELY CONC & INHALING CONTENTS CAN BE HARMFUL/FATAL. USE ONLY W/ADEQ VEN T. AVOID BRTHG VAP & SPRAY MIST. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:IF PERSONAL EXPOSURE CANNOT BE CONTROLLED BELOW APPLICABLE LIMITS BY VENTILATION, WEAR A PROPERLY FITTED ORGANIC VAPOR/PARTICULATE RESPIRATOR APPROVED BY NIOSH FOR PROTECTION. Ventilation:LOC EXHST PREF. GEN EXHST ACCEPTABLE IF EXPOS IS MAINTAINED < APPLIC EXPOS LIM. REFER TO OSHA STDS 1910.91, (SUP DAT) Protective Gloves:IMPERVIOUS GLOVES . Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES . Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING ANSI DESIGN CRITERIA . Work Hygienic Practices:WASH HANDS AFTER USING. AVOID CONTACT WITH SKIN AND EYES. Supplemental Safety and Health TRADE NAME/PART #: PREVENTATIVES & MAINTENANCE PRODUCTS-1. FIRE FIGHT PROC: CONTRS TO PVNT PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO WHEN EXPOSED TO EXTREME HEAT. EFTS OF OVEREXP: W/ADMIN OF ETHYLENE GLYC OL MONOBUTYL ETHER (EGBE) (EXTRACTED FROM DHHS (NIOSH) PUBLICATION #90-118) . VENT: 1910.107, 1910.108. ================== Physical/Chemical Properties ================== Boiling Pt:B.P. Text:>176F,>80C Vapor Pres:SEE INGS Vapor Density:HVR/AIR Evaporation Rate & Reference:FASTER THAN ETHER Appearance and Odor:NONE SPECIFIED BY MANUFACTURER Percent Volatiles by Volume:>25 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES NONE KNOWN. Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER. Hazardous Decomposition Products:BY FIRE: CARBON DIOXIDE, CARBON MONOXIDE, OXIDES OF METALS LISTED IN INGREDIENT SECTION. ==================== Disposal Considerations ==================== Waste Disposal Methods:WASTE FROM THESE PRODUCTS MAY BE HAZARDOUS AS DEFINED UNDER RCRA 40 CFR 261. DO NOT INCINERATE. DEPRESSURIZE CONTAINER. DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE & LOCAL REGULATIONS REGARDING POLLU TION. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.